ㅤ Survey of residential buildings and utilities
The state of engineering communications is one of the main issues that interest citizens living in apartment buildings and owners of commercial real estate. The well-being of life and health of citizens who use the premises for both commercial and residential purposes depends on the performance of these systems. In the conditions of austerity and competition between management companies, little attention is paid to the engineering equipment of buildings.
Many apartment buildings are remnants of the Soviet Union and their engineering infrastructure has not been changed or repaired for years. In this regard, the survey in the housing and utilities sector is one of the most relevant areas. This method allows you to determine the state of engineering networks, identify inconsistencies between the actual networks of the project documentation and the current standards, and determine ways to solve the problems that have occurred in order to restore the efficiency of systems.
These and many other issues should be resolved by the companies that manage the relevant house. However, it is not uncommon that residents have to independently conclude contracts for the audit of engineering networks, in order to identify the causes that adversely affect the lives of citizens. Reports of detected violations, defects, breakdowns and wear of communications become the only reliable confirmation of system failure and its poor performance, and such documentation is an indisputable argument for resolving the issue in court.
Our company performs a survey of engineering networks in connection with the appeal of individuals and legal entities. Verification is carried out within the framework of current legislation and is comprehensive. As a result of a comprehensive check, the customer receives information about the status of the following engineering networks:
- power supply – checks the network status, its operability, load on the network, correct installation and selection of appropriate adapters and protection devices. These events are held in strict accordance with SP 76.13330.2012 "Electrical devices" and SP 134.13330.2012 " telecommunication Systems of buildings and structures. Basic design provisions".
- water supply and sanitation – the system is checked for operability, water pressure, presence of blockages and other impurities affecting the quality of the system, as well as a comprehensive (internal and external) inspection of all pipelines for leaks and deformations. These measures are carried out in strict accordance with SP 31.13330.2012 " water Supply. External networks and constructions" and SP 32.13330.2012 "wastewater disposal. Outdoor networks and structures."
- heat supply, including air and water heating – studies the causes and places of great heat, testing the performance of the network when the applied pressure exceeding the working being tested aerodynamics in the duct system. These events are held in strict accordance with JV 124.13330.2012 "Heating networks", JV 60.13330.2012 "heating, ventilation and air conditioning" and JV 60.13330.2012 "heating, ventilation and air conditioning".
- communication networks-a complete check of the system configuration, security, safety and operability is performed. These measures are carried out in strict accordance with VSN 60-89 "communication devices for signaling and dispatching engineering equipment of residential and public buildings".
- ventilation, air conditioning and cold supply – measurements are made in the ventilation ducts, the operability, efficiency and compliance of the parameters with the norms of SP 60.13330.2012 "heating, ventilation and air conditioning"are checked.
After a complete visual inspection, technical and instrumental measurements, a corresponding report is prepared for each point of inspection, which will allow you to get accurate information about the state of the network, the possibility of increasing efficiency, and will also become the basis for calculating the cost of such work.
Completed works on the survey in the housing and utilities sector
Residential building
G. Kovrov

Determination of the technical condition of a residential building and compliance with the requirements for safe operation
Based on the totality of identified defects, damages and regulatory inconsistencies, the conclusion follows: the building is not suitable for human habitation
Residential building
G. Kovrov

Determination of the technical condition of a residential building and compliance with the requirements for safe operation
Based on the totality of identified defects, damages and regulatory inconsistencies, the conclusion follows: the building is not suitable for human habitation
Residential building
Vladimir region, village Achievement

Quality control of the completed construction and installation works on the Foundation and blind area of the building
During the survey, a number of violations of construction and installation works were identified, recommendations were issued for their elimination
Tenement house
G. Kovrov

Inspection of building structures of a residential building to recognize it as an emergency
The residential building was declared an emergency
Tenement house
kameshkovo city

A survey of the floor slab of an apartment building
To ensure the further safety of the building operation it is recommended to take measures to eliminate the identified defects and damages in accordance with this Technical report
Monolithic Foundation and masonry of an unfinished two-story residential building
Vladimir region, village Pogost

Determining the quality of completed construction work.
The technical condition of the Foundation of the object under investigation is unsatisfactory, and it is necessary to strengthen concrete structures in accordance with the recommendations
Tenement house
G. Kovrov

Determination of the technical condition of external and internal walls, roof and roof structures of a residential apartment building
The construction of external and internal walls of an apartment building does not provide the conditions for strength and poses a threat to the life and health of people.
Service residential building
city of Vladimir

Determination of the technical condition of a residential building and compliance with the requirements for safe operation
To ensure the further safety of the building operation it is recommended to take measures to eliminate the identified defects and damages in accordance with this Technical report
Residential building
kameshkovo city

Determination of the efficiency of the natural ventilation system in residential apartments
According to the results of the survey of the ventilation system of residential apartments in accordance with the provisions of SP 13-102--2003 "Rules for the survey of load-bearing building structures of buildings and structures", the natural ventilation system has the following category of technical condition: limited operable
Tenement house
G. Kovrov

Determination of the efficiency of the natural ventilation system in residential apartments
In order to meet the requirements of SP, SNiP, and SanPiN, a number of measures must be taken to eliminate the detected defects in accordance with the recommendations
Tenement house
G. Kovrov

Determine the category of technical condition of load-bearing floor elements in the premises of a residential building.
To ensure the further safety of the building operation it is recommended to take measures to eliminate the identified defects and damages in accordance with this Technical report
Tenement house
G. Kovrov

Establish the cause of water leaks in the premises of a residential apartment
According to the results of the survey of an apartment building in accordance with the provisions of SP 13-102-2003 "Rules for the survey of load-bearing construction structures of buildings and structures", the roof covering has the following category of technical condition: limited operable.
Residential building
G. Kovrov

Determination of the technical condition of a residential building and compliance with the requirements for safe operation.
The building is not suitable for human habitation
Residential building
G. Kovrov

Determination of the technical condition of a residential building and compliance with the requirements for safe operation
The building is not suitable for human habitation